Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay

Product Details
Customization: Available
Theory: Voltage Relay
Usage: Lathe Relay, Protect Monitoring
Still deciding? Get samples of US$ 30/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (14)
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
  • Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay
Find Similar Products

Basic Info.

Model NO.
RD6-W
Electricity Type
Ac
Load
High Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Rectifier Type
Type
Electric Parameter Relay
Rated Voltage
200-500V AC
Rated Frequency
50/60Hz+-1Hz
Contact Type
2 No/1nc
Contact Material
Agsno
Contact Capacity
5A 280V(AC) 8A30V(DC)
Operating Temperature Range
-45ºC-85ºC
Insulation Class
2.5kv/1mm/1mA/50Hz
Protection Class
IP40
Over/Under Voltage Operation Setting Tim
0.1-20s
Phases Loss /Phases Failure Action Time
0.1-20s
Over Current Set Point
Optional
Indicator
LED Display
Show Voltage Range
150-500V
Max. Counting Times
999999 Times
Max. Timing
999h 59m
Origin
China
HS Code
8431310090
Production Capacity
8000

Product Description

RD6

Phase relay, phase failure, phase reversal, phase loss protection, over-voltage and under-voltage protection


1. Over-voltage and under-voltage protection: When the power supply voltage is too high and too low, it will be cut off and over-voltage and under-voltage value can be set up
2. Phase loss/failure protection,Phase shift
3. Phase sequence protection: when there is an error with the three-phase power, power supply will be cut off
4. It is small and SMT technology is used, with reliable quality and stable performance
5. It can be installed on a standard guide or screw
6. Suitable voltage range 200~500VAC
7. Selecting the appropriate contact material according to different inductive load and resistive load


 
3 Phases Voltage Monitoring Relay : RD6
Rated Voltage 200-500V AC
Rated Frequency 50/60Hz+-1Hz
Contact Type 2 NO/2NC
Contact Material Agcdo
Contact Capacity 5A 280V(AC)8A30V(DC)
Contact Lift 2*107
Operating Temperature Range -45ºC-85ºC
Insulation Class 2.5KV/1mm/1mA/50Hz
Protection Class IP40
Delay output Disabled

Three Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection RelayThree Phase Overvoltage and Undervoltage Protection Rd6-W 3 Phase Protection Relay

RD6 LED status indication Covering voltage 200-500V AC 3 three phase sequence failuture protection control relay

Under/over voltage,asymmetry monitoring relay RD6
Description:
The RD6 DIN mount monitoring protection relay for use in 3 phase sequence voltage, and monitors three phase AC supplies for incorrect phase sequence, phase failure and phase imbalance on systems up to 500V. In 3-phase networks, all phase parameters such as phase failure, phase sequence, and asymmetry should be monitored, RD6 is your best choice

The RD6 provides phase and phase sequence / failure protection. Used to ensure the sequence is correct when connecting 3 phase loads. With an incorrect phase sequence the relay will start to de-energise, preventing the starting of incorrectly connected machinery. The relay will also trip if there is a phase loss and can therefore be used as a phase failure relay.

Green LED indicate the phase sequence and will lit when direction of rotation is correct.

Applications:

Ø Airport cargo belts.
Ø All types of passenger escalators.
Ø Passenger lifts and material lifts.
Ø In conveyor belts, material carrying flat belts.
Ø Industrial process control, and Industrial three phase motors
Ø Generator output power monitoring, and many more.

Features:

Ø DIN Rail Mounting
Ø Phase failure
Ø Phase Imbalance
Ø Incorrect Phase Sequence
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier